Unit: microWatt
                                RO
 
-power[1-*]_average_interval    Power use averaging interval
+power[1-*]_average_interval    Power use averaging interval.  A poll
+                               notification is sent to this file if the
+                               hardware changes the averaging interval.
                                Unit: milliseconds
                                RW
 
+power[1-*]_average_interval_max        Maximum power use averaging interval
+                               Unit: milliseconds
+                               RO
+
+power[1-*]_average_interval_min        Minimum power use averaging interval
+                               Unit: milliseconds
+                               RO
+
 power[1-*]_average_highest     Historical average maximum power use
                                Unit: microWatt
                                RO
                                Unit: microWatt
                                RO
 
+power[1-*]_average_max         A poll notification is sent to
+                               power[1-*]_average when power use
+                               rises above this value.
+                               Unit: microWatt
+                               RW
+
+power[1-*]_average_min         A poll notification is sent to
+                               power[1-*]_average when power use
+                               sinks below this value.
+                               Unit: microWatt
+                               RW
+
 power[1-*]_input               Instantaneous power use
                                Unit: microWatt
                                RO
                                average_highest and average_lowest.
                                WO
 
+power[1-*]_accuracy            Accuracy of the power meter.
+                               Unit: Percent
+                               RO
+
+power[1-*]_alarm               1 if the system is drawing more power than the
+                               cap allows; 0 otherwise.  A poll notification is
+                               sent to this file when the power use exceeds the
+                               cap.  This file only appears if the cap is known
+                               to be enforced by hardware.
+                               RO
+
+power[1-*]_cap                 If power use rises above this limit, the
+                               system should take action to reduce power use.
+                               A poll notification is sent to this file if the
+                               cap is changed by the hardware.  The *_cap
+                               files only appear if the cap is known to be
+                               enforced by hardware.
+                               Unit: microWatt
+                               RW
+
+power[1-*]_cap_hyst            Margin of hysteresis built around capping and
+                               notification.
+                               Unit: microWatt
+                               RW
+
+power[1-*]_cap_max             Maximum cap that can be set.
+                               Unit: microWatt
+                               RO
+
+power[1-*]_cap_min             Minimum cap that can be set.
+                               Unit: microWatt
+                               RO
+
 **********
 * Energy *
 **********