PLLB input and output ranges were wrongly copied from at91sam9261 as the
datasheet didn't mention explicitly PLLB. Correct their values.
This fixes USB.
Reported-by: Andreas Henriksson <andreas.henriksson@endian.se>
Signed-off-by: Boris Brezillon <boris.brezillon@free-electrons.com>
Acked-by: Alexandre Belloni <alexandre.belloni@free-electrons.com>
Tested-by: Andreas Henriksson <andreas.henriksson@endian.se>
Signed-off-by: Nicolas Ferre <nicolas.ferre@atmel.com>
                                        interrupts-extended = <&pmc AT91_PMC_LOCKB>;
                                        clocks = <&main>;
                                        reg = <1>;
-                                       atmel,clk-input-range = <1000000 5000000>;
+                                       atmel,clk-input-range = <1000000 32000000>;
                                        #atmel,pll-clk-output-range-cells = <4>;
-                                       atmel,pll-clk-output-ranges = <70000000 130000000 1 1>;
+                                       atmel,pll-clk-output-ranges = <80000000 200000000 0 1>,
+                                                               <190000000 240000000 2 1>;
                                };
 
                                mck: masterck {