 CPU Idle Cooling
 ================
 dynamic leakage for this period (modulo the energy needed to enter
 this state). So the sustainable power with idle cycles has a linear
 relation with the OPP’s sustainable power and can be computed with a
-coefficient similar to:
+coefficient similar to::
 
            Power(IdleCycle) = Coef x Power(OPP)
 
 --------------------
 
 When we reach the thermal trip point, we have to sustain a specified
-power for a specific temperature but at this time we consume:
+power for a specific temperature but at this time we consume::
 
  Power = Capacitance x Voltage^2 x Frequency x Utilisation
 
 fixed value, ‘Voltage’ and the ‘Frequency’ are fixed artificially
 because we don’t want to change the OPP. We can group the
 ‘Capacitance’ and the ‘Utilisation’ into a single term which is the
-‘Dynamic Power Coefficient (Cdyn)’ Simplifying the above, we have:
+‘Dynamic Power Coefficient (Cdyn)’ Simplifying the above, we have::
 
  Pdyn = Cdyn x Voltage^2 x Frequency
 
 tree. So with the idle injection mechanism, we want an average power
 (Ptarget) resulting in an amount of time running at full power on a
 specific OPP and idle another amount of time. That could be put in a
-equation:
+equation::
 
  P(opp)target = ((Trunning x (P(opp)running) + (Tidle x P(opp)idle)) /
                        (Trunning + Tidle)
 
 At this point if we know the running period for the CPU, that gives us
 the idle injection we need. Alternatively if we have the idle
-injection duration, we can compute the running duration with:
+injection duration, we can compute the running duration with::
 
  Trunning = Tidle / ((P(opp)running / P(opp)target) - 1)
 
    target residency, otherwise we end up consuming more energy and
    potentially invert the mitigation effect
 
-So the final equation is:
+So the final equation is::
 
  Trunning = (Tidle - Twakeup ) x
                (((P(opp)dyn + P(opp)static ) - P(opp)target) / P(opp)target )