Currently clk_get_sys is used with cpu-cluster.<n> as the device id
which is incorrect. It should be connection/consumer ID instead.
It is possible to specify input clock in the cpu device node along
with the optional clock-name. clk_get_sys can't handle that.
This patch replaces clk_get_sys with clk_get to extend support for
clocks specified in the device tree cpu node.
Signed-off-by: Sudeep KarkadaNagesha <sudeep.karkadanagesha@arm.com>
Acked-by: Viresh Kumar <viresh.kumar@linaro.org>
Signed-off-by: Rafael J. Wysocki <rafael.j.wysocki@intel.com>
        }
 
        name[12] = cluster + '0';
-       clk[cluster] = clk_get_sys(name, NULL);
+       clk[cluster] = clk_get(cpu_dev, name);
        if (!IS_ERR(clk[cluster])) {
                dev_dbg(cpu_dev, "%s: clk: %p & freq table: %p, cluster: %d\n",
                                __func__, clk[cluster], freq_table[cluster],