]> www.infradead.org Git - users/hch/misc.git/commitdiff
HID: hid-input: only ignore 0 battery events for digitizers
authorDmitry Torokhov <dmitry.torokhov@gmail.com>
Wed, 15 Oct 2025 04:28:44 +0000 (21:28 -0700)
committerJiri Kosina <jkosina@suse.com>
Wed, 15 Oct 2025 15:14:39 +0000 (17:14 +0200)
Commit 581c4484769e ("HID: input: map digitizer battery usage") added
handling of battery events for digitizers (typically for batteries
presented in stylii). Digitizers typically report correct battery levels
only when stylus is actively touching the surface, and in other cases
they may report battery level of 0. To avoid confusing consumers of the
battery information the code was added to filer out reports with 0
battery levels.

However there exist other kinds of devices that may legitimately report
0 battery levels. Fix this by filtering out 0-level reports only for
digitizer usages, and continue reporting them for other kinds of devices
(Smart Batteries, etc).

Reported-by: 卢国宏 <luguohong@xiaomi.com>
Fixes: 581c4484769e ("HID: input: map digitizer battery usage")
Signed-off-by: Dmitry Torokhov <dmitry.torokhov@gmail.com>
Signed-off-by: Jiri Kosina <jkosina@suse.com>
drivers/hid/hid-input.c

index 5d7532d79d21c1476e7ed2d332dad368cf464386..e56e7de5327993c8cb4d16700a5f98a9662f31e2 100644 (file)
@@ -635,7 +635,10 @@ static void hidinput_update_battery(struct hid_device *dev, unsigned int usage,
                return;
        }
 
-       if (value == 0 || value < dev->battery_min || value > dev->battery_max)
+       if ((usage & HID_USAGE_PAGE) == HID_UP_DIGITIZER && value == 0)
+               return;
+
+       if (value < dev->battery_min || value > dev->battery_max)
                return;
 
        capacity = hidinput_scale_battery_capacity(dev, value);