]> www.infradead.org Git - users/dwmw2/linux.git/commit
net: phy: marvell-88q2xxx: Fix temperature measurement with reset-gpios
authorDimitri Fedrau <dima.fedrau@gmail.com>
Sat, 18 Jan 2025 18:43:43 +0000 (19:43 +0100)
committerPaolo Abeni <pabeni@redhat.com>
Thu, 23 Jan 2025 08:55:06 +0000 (09:55 +0100)
commita197004cf3c2e6c8cc0695c787a97e62e3229754
tree7be8d723e44c8ee9fd8c0b03a6ea4a24802ac6e5
parent92e5995773774a3e70257e9c95ea03518268bea5
net: phy: marvell-88q2xxx: Fix temperature measurement with reset-gpios

When using temperature measurement on Marvell 88Q2XXX devices and the
reset-gpios property is set in DT, the device does a hardware reset when
interface is brought down and up again. That means that the content of
the register MDIO_MMD_PCS_MV_TEMP_SENSOR2 is reset to default and that
leads to permanent deactivation of the temperature measurement, because
activation is done in mv88q2xxx_probe. To fix this move activation of
temperature measurement to mv88q222x_config_init.

Fixes: a557a92e6881 ("net: phy: marvell-88q2xxx: add support for temperature sensor")
Reviewed-by: Niklas Söderlund <niklas.soderlund+renesas@ragnatech.se>
Signed-off-by: Dimitri Fedrau <dima.fedrau@gmail.com>
Reviewed-by: Andrew Lunn <andrew@lunn.ch>
Link: https://patch.msgid.link/20250118-marvell-88q2xxx-fix-hwmon-v2-1-402e62ba2dcb@gmail.com
Signed-off-by: Paolo Abeni <pabeni@redhat.com>
drivers/net/phy/marvell-88q2xxx.c