iio: light: veml6030: fix microlux value calculation
authorJavier Carrasco <javier.carrasco.cruz@gmail.com>
Wed, 16 Oct 2024 17:04:31 +0000 (19:04 +0200)
committerJonathan Cameron <Jonathan.Cameron@huawei.com>
Thu, 24 Oct 2024 17:30:03 +0000 (18:30 +0100)
commit63dd163cd61dda6f38343776b42331cc6b7e56e0
tree7fa8aeb965610825deb82b2aee1786cc83d98bf2
parent369f05688911b05216cfcd6ca74473bec87948d7
iio: light: veml6030: fix microlux value calculation

The raw value conversion to obtain a measurement in lux as
INT_PLUS_MICRO does not calculate the decimal part properly to display
it as micro (in this case microlux). It only calculates the module to
obtain the decimal part from a resolution that is 10000 times the
provided in the datasheet (0.5376 lux/cnt for the veml6030). The
resulting value must still be multiplied by 100 to make it micro.

This bug was introduced with the original implementation of the driver.

Only the illuminance channel is fixed becuase the scale is non sensical
for the intensity channels anyway.

Cc: stable@vger.kernel.org
Fixes: 7b779f573c48 ("iio: light: add driver for veml6030 ambient light sensor")
Signed-off-by: Javier Carrasco <javier.carrasco.cruz@gmail.com>
Link: https://patch.msgid.link/20241016-veml6030-fix-processed-micro-v1-1-4a5644796437@gmail.com
Signed-off-by: Jonathan Cameron <Jonathan.Cameron@huawei.com>
drivers/iio/light/veml6030.c