soc/tegra: cbb: Use correct master_id mask for CBB NOC in Tegra194
In Tegra194 SoC, master_id bit range is different between cluster NOC
and CBB NOC. Currently same bit range is used which results in wrong
master_id value. Due to this, illegal accesses from the CCPLEX master
do not result in a crash as expected. Fix this by using the correct
range for the CBB NOC.
Finally, it is only necessary to extract the master_id when the
erd_mask_inband_err flag is set because when this is not set, a crash
is always triggered.